Model STElectric Steam Boiler

  • KW Rating
    15-4,000 KW
  • Voltage
    208, 240, 308, 415, 480, 600
  • Steam LB/Hour
    51-13,800 PPH
  • Horsepower
    1.5-400 BHP
  • Pressures
    15-200 PSI
Model ST Electric Steam Boiler

Despite its compact footprint, the Model ST Electric Steam Boiler’s large steam chest delivers high quality, dry steam with minimum carryover. Fuel-oil or propane boiler retrofits are simpler with a Precision Boiler Model ST Electric Steam Boiler that requires no vent stack or combustion air louvers.

Options

The standard ST Electric Steam Boiler can be customized with a variety of factory installed options or configured to connect with field mounted interfaces, giving you exceptional flexibility in design and specification. Adding an SCR creates a boiler with 100:1 turndown to precisely follow the process demand.

Features & Benefits

  • Custom models can be supplied in a ‘knock-down’ condition to fit through narrow entries
  • Each heating element is fitted with its own 2-1/2” square mounting flange, individually installed in either one or both head(s) of the vessel to simplify maintenance and reduce downtime
  • Step Circuit Enable/Disable switches make it easy to limit boiler’s maximum firing rate when other higher priority electric loads are peaking
  • Optional SCR control provides near infinite modulation to precisely follow heating load while minimizing energy usage
  • Requires no vent stack, breeching, or combustion air louvers, which reduces total installation costs and speeds up completion
Model ST Electric Steam Boiler

Despite its compact footprint, the Model ST Electric Steam Boiler’s large steam chest delivers high quality, dry steam with minimum carryover. Fuel-oil or propane boiler retrofits are simpler with a Precision Boiler Model ST Electric Steam Boiler that requires no vent stack or combustion air louvers.

Options

The standard ST Electric Steam Boiler can be customized with a variety of factory installed options or configured to connect with field mounted interfaces, giving you exceptional flexibility in design and specification. Adding an SCR creates a boiler with 100:1 turndown to precisely follow the process demand.

Features & Benefits

  • Custom models can be supplied in a ‘knock-down’ condition to fit through narrow entries
  • Each heating element is fitted with its own 2-1/2” square mounting flange, individually installed in either one or both head(s) of the vessel to simplify maintenance and reduce downtime
  • Step Circuit Enable/Disable switches make it easy to limit boiler’s maximum firing rate when other higher priority electric loads are peaking
  • Optional SCR control provides near infinite modulation to precisely follow heating load while minimizing energy usage
  • Requires no vent stack, breeching, or combustion air louvers, which reduces total installation costs and speeds up completion

Models

Models

Features

Options

Data Data

  • High-pressure process steam
  • Hydronic heating
  • Hot water
  • Humidification

This site uses cookies. By continuing to browse this site you are agreeing to our use of cookies. View our Privacy Policy.